PSOD and VMFS corruption can occur when using HPE Rebranded Qlogic QLE269x series HBAs on HPE/Hitachi Servers (76353)
Symptoms
When using HPE rebranded Qlogic QLE269x HBAs, ESXi host fails with PSOD as well as potentially VMFS corruption. This applies to the HPE rebranded HBAs SN1100Q & SN1600Q

The most common indicator of an issue with the QLE269x chipset is the following message in /var/log/vmkernel.log, usually repeated numerous times leading up to the PSOD:
WARNING: qlnativefc: vmhba2(12:0.0): Invalid ISP SCSI completion handle(281) req=1
WARNING: qlnativefc: vmhba2(12:0.0): Invalid ISP SCSI completion handle(282) req=1
WARNING: qlnativefc: vmhba2(12:0.0): Invalid ISP SCSI completion handle(284) req=1

Below are additional qlnativefc driver messages that have been observed around the time of the PSOD:
qlnativefc: vmhba3(12:0.1): Inside qlnativefcAbortIsp
qlnativefc: vmhba3(12:0.1): Performing ISP error recovery - ha= 0x4308e6398b50.
qlnativefc: vmhba2(12:0.0): Inconsistent NVRAM detected: checksum=0x8c54d9ed id=^@ version=0x0.
qlnativefc: vmhba2(12:0.0): Falling back to functioning (yet invalid -- WWPN) defaults.
qlnativefc: vmhba2(12:0.0): 83XX: F/W Error Reported: Check if reset required.
qlnativefc: vmhba2(12:0.0): Heartbeat Failure encountered, chip reset required.
https://kb.vmware.com/s/article/76353

уже было - https://robopet3.dreamwidth.org/8890.html, но обновилось.
PSOD and VMFS corruption can occur when using HPE Rebranded Qlogic QLE269x series HBAs on HPE/Hitachi Servers (76353)

https://kb.vmware.com/s/article/76353

Profile

robopet3

May 2023

S M T W T F S
 12 3456
78910111213
14151617181920
21222324252627
28293031   

Syndicate

RSS Atom

Most Popular Tags

Style Credit

Expand Cut Tags

No cut tags
Page generated Dec. 4th, 2025 01:52 am
Powered by Dreamwidth Studios